Contents (per one capsule)

  • HOTU : ca. 0.25 mmol

Directions for Use

  • Each capsule contains all reagents for a single use on 0.25 mmol scale condensation reaction (amide coupling reaction) between carboxylic acid and amine.
    Typical condition: 0.25 mmol of carboxylic acid and 1.25 equiv. of amines and 2.0 equiv. of base in DMF (0.25 M) at 30 °C.

Related Products

  • E1306 HOTU

Artikel # R0297
Summenformel / Molekülmasse C__1__0H__1__7F__6N__4O__3P = 386.24 
Physikalischer Zustand (20 °C) Solid
Lagerungstemperatur Refrigerated (0-10°C)
Zu vermeidende Bedingungen Heat Sensitive
CAS RN 333717-40-1
Spezifikation
Appearance White to Almost white capsule
Functionality test (conversion ratio) min.85.0 %
Eigenschaften
GHS
Piktogramm Pictogram
Signalwort Achtung
Gefahrenhinweise H302 + H312 + H332 : Gesundheitsschädlich bei Verschlucken, Hautkontakt oder Einatmen.
H315 : Verursacht Hautreizungen.
H319 : Verursacht schwere Augenreizung.
Sicherheitshinweise P261 : Einatmen von Staub vermeiden.
P264 : Nach Gebrauch Haut gründlich waschen.
P280 : Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz/ Gehörschutz Tragen.
P337 + P313 : Bei anhaltender Augenreizung: Ärztlichen Rat einholen/ ärztliche Hilfe hinzuziehen.
P302 + P352 + P312 : BEI BERÜHRUNG MIT DER HAUT: Mit viel Wasser waschen. Bei Unwohlsein GIFTINFORMATIONSZENTRUM/Arzt anrufen.
P304 + P340 + P312 : BEI EINATMEN: Die Person an die frische Luft bringen und für ungehinderte Atmung sorgen. Bei Unwohlsein GIFTINFORMATIONSZENTRUM/Arzt anrufen.
Verwandte Gesetze:
Transportinformationen:
HS-Nr. (Import / Export) (TCI-E) 3822190090
Anwendung
TCI Practical Example: The Condensation Reaction Using HOTU in a Capsule Reagent

TCI反応実例:HOTU入りカプセル試薬を用いた縮合反応

Used Chemicals

Procedure

Reagents for condensation capsule (HOTU) (one capsule) was added to a solution of 4-bromobenzoic acid (50 mg, 0.25 mmol, 1.0 eq.), morpholine (27 μL, 0.31 mmol, 1.25 eq.) and N,N-diisopropylethylamine (85 μL, 0.50 mmol, 2 eq.) in DMF (1 mL) at r.t. and the mixture was stirred at 30 °C for 2 hours. After the reaction, the mixture was diluted with ethyl acetate (15 mL) and filtered through Celite to remove HPMC. The filtrate was washed with sat. Na2SO4 aq. (10 mL), 2 mol/L HCl aq. (10 mL), sat. NaHCO3 aq. (10 mL) and brine (10 mL). The organic layer was dried over sodium sulfate and concentrated under reduced pressure. The crude product was purified by silica gel chromatography (hexane:ethyl acetate = 2:1 - 1:1) to afford (4-bromophenyl)(morpholino)methanone (54 mg, 80% yield) as a white solid.

Experimenter’s Comments

The reaction mixture was monitored by UPLC.
The shape of the capsule is like below image and each capsule includes ca. 0.25 mmol of HOTU.
The material of the capsule is water-soluble HPMC (hydroxypropyl methylcellulose).
HPMC was removed with filtration through Celite pad and saturated sodium sulfate solution used in the participation, but separating funnel was clogged due to the precipitation of sodium sulfate. Therefore, the precipitated sodium sulfate was filtered, and ethyl acetate was added to the filtrate for extraction. Use of a more dilute sodium sulfate solution may reduce clogging problems.

カプセル

Analytical Data

(4-Bromophenyl)(morpholino)methanone

1H NMR (400 MHz, CDCl3); δ 7.57 (d, J = 8.4 Hz, 2H), 7.30 (d, J = 8.4 Hz, 2H), 3.74-3.44 (m, 8H).

Lead Reference

Other Reference


Produktartikel
Produktdokumente (Hinweis: Für einige Produkte sind keine Analysediagramme verfügbar.)
Sicherheitsdatenblatt (SDB)
Bitte wählen Sie Sprache.

Das angeforderte SDB ist nicht verfügbar.

Bitte Kontaktieren Sie uns für mehr Informationen.

Spezifikationsdokumenten
AZ & andere Zertifikate
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das Produkt mit der gesuchten Lotnummer wude eingestellt und die dazugehörige Dokumentation wird nicht mehr bereitgestellt. Bitte probieren Sie verschiedene Lotnummern für dieses Produkt aus.

Muster-AZ
Dies ist ein Muster-AZ und repräsentiert möglicherweise nicht eine kürzlich hergestellte Charge des Produkts.

Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.

Analytische Diagramme
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.

Das Produkt mit der gesuchten Lotnummer wude eingestellt und die dazugehörige Dokumentation wird nicht mehr bereitgestellt. Bitte probieren Sie verschiedene Lotnummern für dieses Produkt aus.

Andere Dokumente

Sitzungsstatus
Ihre Sitzung wird in 10 Minuten beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen. Minute beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen.

Deine Sitzung ist abgelaufen. Sie werden auf die Startseite weitergeleitet.