CAS RN: 250285-32-6 | Produkte #: R0316

1,3-Bis(2,6-diisopropylphenyl)imidazolium Chloride (HPMC encapsulated)


New
Reinheit:
Synonyme
Produktdokumente:
10EACH
65,00 €
Kontaktieren Sie uns 19  

*In Belgien verfügbare Lagerbestände werden in 1 bis 3 Tagen geliefert.
*In Japan verfügbare Lagerbestände werden in 1 bis 2 Wochen geliefert. (unter Ausschluss von regulierten Artikeln und Trockeneislieferungen).


Ergänzende Produktinformation:

Contents (per one capsule)

  • IPr·HCl ca. 0.125 mmol

Uses of Reagent

  • Applicable to palladium-catalyzed reactions due to a ligand encapsulated in HPMC capsules

Soluble Solvents

  • Water, DMSO, DMF, 1,4-Dioxane (50°C), THF/Water mixture, 1,2-Dimethoxyethane/Water mixture

Related Product

  • D3611 1,3-Bis(2,6-diisopropylphenyl)imidazolium Chloride

Artikel # R0316
Summenformel / Molekülmasse C__2__7H__3__7ClN__2 = 425.06 
Physikalischer Zustand (20 °C) Solid
Lagerungstemperatur Room Temperature (Recommended in a cool and dark place, <15°C)
Unter Inertgas lagern Store under inert gas
Zu vermeidende Bedingungen Hygroscopic
CAS RN 250285-32-6
Spezifikation
Appearance White to Almost white capsule
Functionality test (conversion ratio) min.80.0 %
Eigenschaften
GHS
Piktogramm Pictogram
Signalwort Achtung
Gefahrenhinweise H315 : Verursacht Hautreizungen.
H319 : Verursacht schwere Augenreizung.
Sicherheitshinweise P264 : Nach Gebrauch Haut gründlich waschen.
P280 : Schutzhandschuhe/ Augenschutz/ Gesichtsschutz tragen.
P302 + P352 : BEI BERÜHRUNG MIT DER HAUT: Mit viel Wasser waschen.
P337 + P313 : Bei anhaltender Augenreizung: Ärztlichen Rat einholen/ ärztliche Hilfe hinzuziehen.
P362 + P364 : Kontaminierte Kleidung ausziehen und vor erneutem Tragen waschen.
P332 + P313 : Bei Hautreizung: Ärztlichen Rat einholen/ ärztliche Hilfe hinzuziehen.
Verwandte Gesetze:
Transportinformationen:
HS-Nr. (Import / Export) (TCI-E) 3822190090
Anwendung
TCI Practical Example: Suzuki-Miyaura Coupling Using the Encapsulated Pd2(dba)3 and IPr·HCl

TCI Practical Example:Suzuki-Miyaura Coupling Using the Encapsulated Pd2(dba)3 and IPr·HCl

Used Chemicals

Procedure

Pd2(dba)3 (HPMC encapsulated) (one capsule) and IPr·HCl (HPMC encapsulated) (one capsule) were added to a solution of 2-acetamido-5-bromo-4-methylpyridine (286mg, 1.25 mmol), cesium carbonate (448 mg, 1.38 mmol, 1.1 eq.) and phenylboronic acid (229 mg, 1.88 mmol, 1.5 eq.) in THF/water (10:1, 7.1 mL) at room temperature and the reaction mixture was stirred at 100 °C for 2 hours. The solution was then diluted with ethyl acetate (3.2 mL) and sat. Na2SO4 aq. (3.2mL), and filtered through Celite pad. The filtrate was separated and the organic layer was washed with water (15 mL) and brine (15 mL), dried over sodium sulfate and concentrated under reduced pressure. The crude product was purified by silica gel chromatography (ethyl acetate: hexane = 1:2 - 1:1) to afford 2-acetamido-4-methyl-5-phenylpyridine (294 mg, 96% yield) as a white solid.

Experimenter’s Comments

The reaction mixture was monitored by GC.
The material of the capsule is water-soluble HPMC (hydroxypropyl methylcellulose).
The shape of the capsule is like the image below and Pd2(dba)3 (ca. 60 μmol) and IPr·HCl (ca. 125 μmol) are encapsulated in each capsule, respectively.

Appearance of capsule

The capsule disintegrates as shown in the image below when stirred in the solvent for about 15 minutes, releasing its content.

Capsule disintegrating

Analytical Data

2-Acetamido-4-methyl-5-phenylpyridine

1H NMR (400 MHz, CDCl3); δ 9.24-9.06 (brs, 1H), 8.16 (s, 1H), 8.10 (s, 1H), 7.46-7.36 (m, 3H), 7.30-7.29 (m, 2H), 2.32 (s, 3H), 2.21 (s, 3H).

Lead Reference

Other References


Produktdokumente (Hinweis: Für einige Produkte sind keine Analysediagramme verfügbar.)
Sicherheitsdatenblatt (SDB)
Bitte wählen Sie Sprache.

Das angeforderte SDB ist nicht verfügbar.

Bitte Kontaktieren Sie uns für mehr Informationen.

Spezifikationsdokumenten
AZ & andere Zertifikate
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das Produkt mit der gesuchten Lotnummer wude eingestellt und die dazugehörige Dokumentation wird nicht mehr bereitgestellt. Bitte probieren Sie verschiedene Lotnummern für dieses Produkt aus.

Muster-AZ
Dies ist ein Muster-AZ und repräsentiert möglicherweise nicht eine kürzlich hergestellte Charge des Produkts.

Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.

Analytische Diagramme
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.

Das Produkt mit der gesuchten Lotnummer wude eingestellt und die dazugehörige Dokumentation wird nicht mehr bereitgestellt. Bitte probieren Sie verschiedene Lotnummern für dieses Produkt aus.

Andere Dokumente

Sitzungsstatus
Ihre Sitzung wird in 10 Minuten beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen. Minute beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen.

Deine Sitzung ist abgelaufen. Sie werden auf die Startseite weitergeleitet.