Published TCIMAIL newest issue No.201
Maximum quantity allowed is 999
CAS RN: 994-30-9 | Produkte #: T0589
Chlorotriethylsilane
Reinheit: >97.0%(GC)
- Triethylsilyl Chloride
- Triethylchlorosilane
- TES-Cl
*Lagerbestand in Belgien: Versand am selben Tag
*Lagerbestand in Japan: Bitte prüfen Sie die Versandsimulation für voraussichtliche Lieferzeiten. (ausgenommen regulierte Produkte und Trockeneissendungen)
| Artikel # | T0589 |
Reinheit / Analysenmethode
|
>97.0%(GC) |
| Summenformel / Molekülmasse | C__6H__1__5ClSi = 150.72 |
| Physikalischer Zustand (20 °C) | Liquid |
Lagerungstemperatur
|
Room Temperature (Recommended in a cool and dark place, <15°C) |
| Unter Inertgas lagern | Store under inert gas |
| Zu vermeidende Bedingungen | Moisture Sensitive |
| CAS RN | 994-30-9 |
| Reaxys Registrierungsnummer | 1732860 |
| PubChem-Stoff-ID | 87576486 |
| Spektrale Daten (AIST) Link | 5610 |
| MDL-Nummer | MFCD00000507 |
| Appearance | Colorless to Light yellow clear liquid |
| Purity(GC) | min. 97.0 % |
| Siedepunkt | 149 °C |
| Flammpunkt | 30 °C |
| Spezifisches Gewicht (20/20) | 0.90 |
| Brechungsindex | 1.43 |
| Piktogramm |
|
| Signalwort | Gefahr |
| Gefahrenhinweise | H314 : Verursacht schwere Verätzungen der Haut und schwere Augenschäden. H226 : Flüssigkeit und Dampf entzündbar. H290 : Kann gegenüber Metallen korrosiv sein. |
| Sicherheitshinweise | P210 : Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen. P280 : Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz/ Gehörschutz Tragen. P370 + P378 : Bei Brand: Trockensand, Löschpulver oder alkoholbeständigen Schaum zum Löschen verwenden. P303 + P361 + P353 : BEI BERÜHRUNG MIT DER HAUT (oder dem Haar): Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen. P304 + P340 + P310 : BEI EINATMEN: Die Person an die frische Luft bringen und für ungehinderte Atmung sorgen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen. P305 + P351 + P338 + P310 : BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen. |
| EC-Nummern | 213-615-6 |
| UN-Nummer | UN2986 |
| Klasse | 8 / 3 |
| Verpackungsgruppe (DOT-AIR) | II |
| HS-Nr. (Import / Export) (TCI-E) | 2931900090 |
-
Used Chemicals
-
Procedure
-
To a solution of (±)-1-phenylethyl alcohol (0.242 mL, 2.0 mmol) in THF (4 mL, 0.5 mol/L) was added imidazole (204 mg, 3.0 mmol), then TESCl (0.402 mL, 2.4 mmol) was added dropwise and the mixture was stirred at room temperature for 2 hours. Water (10 mL), ethyl acetate (20 mL) was added to the reaction mixture to quench and was extracted with ethyl acetate (10 mL x 3). The combined organic layer was dried over sodium sulfate and filtered. The solvent was removed under reduced pressure and the residue was purified by column chromatography (ethyl acetate:hexane = 0:100 - 3:97 on silica gel) to give triethyl((±)-1-phenylethoxy)silane as a colorless liquid (373 mg, 79%).
-
Experimenter’s Comments
-
The reaction mixture was monitored by TLC (ethyl acetate:hexane = 1:20, Rf = 0.70).
-
Analytical Data
-
triethyl((±)-1-phenylethoxy)silane
1H NMR (270 MHz, CDCl3); δ 7.36-7.18 (m, 5H), 4.86 (q, 1H, J = 6.2 Hz), 1.42 (d, 1H, J = 6.2 Hz), 0.94-0.87 (m, 9H), 0.64-0.51 (m, 6H).
-
Lead Reference
-
- Synthetic Versatility of Lipases: Application for Si-O Bond Formation and Cleavage
Sicherheitsdatenblatt (SDB)
Das angeforderte SDB ist nicht verfügbar.
Bitte Kontaktieren Sie uns für mehr Informationen.
text.sds.search.errormsg.content.1.kishida
Spezifikationsdokumenten
Die angeforderten Spezifikationen sind nicht verfügbar.
Bitte Kontaktieren Sie uns für mehr Informationen.
text.specification.search.errormsg.content.1.kishida
AZ & andere Zertifikate
Bitte überprüfen Sie, ob die von Ihnen eingegebene Chargennummer korrekt ist. Sie besteht aus 4-5 alphanumerischen Zeichen vor dem Bindestrich. Bitte prüfen Sie sorgfältig, ob O (Alphabet) oder 0 (Zahl), "I (Alphabet) oder 1 (Zahl) im Besonderen.
Wenn Ihre Eingabe korrekt ist und Sie dennoch das Zerifikat nicht angezeigt bekommen, kontaktieren Sie uns bitte.
text.certificate.analysis.pdf.errormsg.content6.kishida
Muster-AZ
Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.
Analytische Diagramme
Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.