CAS RN: 564483-18-7 | Numéro de produit: R0302

Xphos (HPMC encapsulated)

Chemical Structure of Xphos  (HPMC encapsulated)

New
Pureté:
Synonymes
Documents de produit:
10EACH
€60.00
Contactez-nous 29  

*Stock disponible en Belgique : Expédition le jour même
*Stock disponible au Japon : Veuillez consulter la simulation d'expédition pour une estimation des délais d'expédition (hors articles réglementés et expédition avec Carboglace)


Informations supplémentaires sur le produit:

Contents (per one capsule)

  • Xphos ca. 0.125 mmol

Uses of Reagent

  • Applicable to palladium-catalyzed reactions due to a ligand encapsulated in HPMC capsules

Soluble Solvents

  • Water, DMSO, DMF, 1,4-Dioxane (50°C), THF/Water mixture, 1,2-Dimethoxyethane/Water mixture

Related Product

  • D5038 2-Dicyclohexylphosphino-2',4',6'-triisopropylbiphenyl

Numéro de produit R0302
Formule moléculaire / poids moléculaire C__3__3H__4__9P = 476.73 
Etat physique (20 ° C) Solid
Condition de stockage Room Temperature (Recommended in a cool and dark place, <15°C)
Stocker sous gaz inerte Store under inert gas
Condition à éviter Hygroscopic
CAS RN 564483-18-7
Spécifications
Appearance White to Almost white capsule
Functionality test (conversion ratio) min.90.0 %
Propriétés
SGH
Pictogramme Pictogram
Mot de signal Attention
Mentions de danger H315 : Provoque une irritation cutanée.
H319 : Provoque une sévère irritation des yeux.
Conseils de prudence P264 : Se laver la peau soigneusement après manipulation.
P280 : Porter des gants de protection/ un équipement de protection des yeux/ du visage.
P302 + P352 : EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment à l’eau.
P337 + P313 : Si l'irritation oculaire persiste: consulter un médecin.
P362 + P364 : Enlever les vêtements contaminés et les laver avant réutilisation.
P332 + P313 : En cas d'irritation cutanée: consulter un médecin.
Lois connexes:
Informations de transport:
N ° SH (import / export) (TCI-E) 3822190090
Application
TCI Practical Example: Suzuki-Miyaura Coupling Using the Encapsulated Pd2(dba)3 and the Encapsulated Xphos

TCI Practical Example: Suzuki-Miyaura Coupling Using the Encapsulated Pd2(dba)3 and the Encapsulated Xphos

Used Chemicals

Procedure

Pd2(dba)3 (HPMC encapsulated) (one capsule) and XPhos (HPMC encapsulated) (one capsule) were added to a solution of 4-bromoanisole (1.21 g, 6.47 mmol), cesium carbonate (6.32 g, 19.4 mmol, 3 eq.) and potassium phenyltrifluoroborate (1.43 g, 7.76 mmol, 1.2 eq.) in THF/water (4:1, 20 mL) at room temperature and the reaction mixture was stirred at 65 °C for 2 hours. The solution was then diluted with ethyl acetate (15 mL) and sat. Na2SO4 aq. (15 mL), and filtered through Celite pad. The filtrate was extracted with ethyl acetate (10 mL x 2) and the organic layer was washed with water (10 mL) and brine (10 mL), dried over sodium sulfate and concentrated under reduced pressure. The crude product was purified by silica gel chromatography (hexane) to afford 4-methoxybiphenyl (1.09 g, 90% yield) as a white solid.

Experimenter’s Comments

The reaction mixture was monitored by UPLC.
The material of the capsule is water-soluble HPMC (hydroxypropyl methylcellulose).
The capsule has the shape shown in Fig. 1 and XPhos (ca. 125 μmol) and Pd2(dba)3 (ca. 60 μmol) are encapsulated in each capsule, respectively.

Appearance of capsule
Fig. 1. Appearance of capsule
The capsule dissolves in water or polar solvent as shown in Fig. 2.
Appearance of capsule
Fig. 2. Capsule disintegrating
(left) Immediately after the addition of the capsule,
(right) 15 minutes after the addition of the capsule.

Analytical Data

4-Methoxybiphenyl

1H NMR (400 MHz, CDCl3); δ 7.55-7.50 (m, 4H), 7.42-7.38 (t, J = 7.6 Hz, 2H), 7.31-7.27 (t, J = 7.6 Hz,1H), 6.98-6.95 (d, J = 9.2 Hz, 2H), 3.84 (s, 3H).

Lead Reference

Other Reference


Articles de produit
Documents de produit (Note : Pour certains produits, les tableaux analytiques ne sont pas disponibles.)
Fiche de sécurité (FDS)
S'il vous plaît sélectionnez la langue.

La FDS demandée n'est pas disponible.

Nous contacter pour plus d'informations.

Spécifications
CoA et autres Certificats
Veuillez remplir le numéro de lot Le numéro de lot saisi est incorrect. Veuillez saisir uniquement 4-5 caractères alphanumériques avant le trait d'union.

Le numéro de lot recherché n'est plus disponible et la documentation correspondante n'est plus fournie. Veuillez essayer avec un autre numéro de lot pour ce produit.

Exemple de CoA
Il s'agit d'un échantillon CoA qui peut ne pas représenter un lot récemment fabriqué du produit.

Un échantillon CoA pour ce produit n'est pas disponible pour le moment.

Graphiques analytiques
Veuillez remplir le numéro de lot Le numéro de lot saisi est incorrect. Veuillez saisir uniquement 4-5 caractères alphanumériques avant le trait d'union.

Le tableau analytique demandé n'est pas disponible. Nous sommes désolés pour ce désagrément.

Le numéro de lot recherché n'est plus disponible et la documentation correspondante n'est plus fournie. Veuillez essayer avec un autre numéro de lot pour ce produit.

Autres documents

État de la session
Votre session expirera dans 10 minutes. Vous serez redirigé vers la page d'accueil après l'expiration de la session. Veuillez cliquer sur le bouton pour continuer la session à partir de la même page. minute. Vous serez redirigé vers la page d'accueil après l'expiration de la session. Veuillez cliquer sur le bouton pour continuer la session à partir de la même page.

Votre session a expiré. Vous serez redirigé vers la page d'accueil.

Changer de région entraînera la fermeture de votre session actuelle. Souhaitez-vous continuer ?