This kit contains buffers and anti-NeuN antibody (positive control) for 3D nuclear staining of CUBIC-cleared tissues.
The difference between CUBIC-HV™1 3D immunostaining kit (Product No. C3708) and CUBIC-HV™1 3D immunostaining kit (Casein separately) (Product No. C3717):
CUBIC-HV™1 3D immunostaining kit (Product No. C3708) includes a buffer with casein, which can be used as soon as it is arrived. The buffer with casein should be used as soon as possible.
CUBIC-HV™1 3D immunostaining kit (Casein separately) (Product No. C3717) includes a buffer without casein and casein is in the kit separately. The casein should be mixed to the buffer just before use and after mixing, the buffer should be used as soon as possible. It takes about 2 hours to solve the casein.
Please see the detail protocols in CUBICStars’ web site.
https://www.cubicstars.com/cubic-hv/index.html
Constituents in kit (suitable for a brain of an adult mouse)
Process outline
====Delipidation====
Perfusion fixation and dissection of the mouse brain
Post-fix <24 h
Wash (PBS) 2 h x3
Delipidation (CUBIC-L; Product No. T3740) 3-7 days
Wash (PBS) 2 h x3
====Nuclear staining by CUBIC-HV™1 3D nuclear staining kit (Product No. C3709) ====
Nuclear staining (DAPI or Propidium Iodide or others in CUBIC-HV™1 3D nuclear staining buffer) 3-5 days
Wash (3D nuclear staining wash buffer; 10mM HEPES buffer, pH 7.5) 2 h x3
==== Optional process; Enzyme reaction ====
====Immunostaining by CUBIC-HV™1 3D immunostaining kit (Casein separately) (Product No. C3717) ====
Add the entire amount of casein powder in the kit (1 vial) to the 3D immunostaining buffer (without Casein). It takes about 2 hours at room temperature.
From this time on, 3D immunostaining buffer including Casein should be used.
Primary antibody (anti NeuN antibody in C3717 kit can be used): 5 µg/whole brain
Secondary antibody: anti-Fc Fab (out of the kits), 3.75 µg/whole brain
Primary antibody + secondary antibody reaction / Replacement with CUBIC-HV™1 3D immunostaining buffer, 1.5 h
Immunostaining (CUBIC-HV™1 3D immunostaining buffer with CUBIC-HV™1 3D immunostaining additive (if required)), >1 week
Reaction in the same buffer at 4°C, 1 day
Wash (CUBIC-HV™1 3D immunostaining wash buffer), 2 h x3
====Fix and RI matching====
Post-fix (in 1% Formaldehyde Solution), 1 day
Wash (PBS), 2 h
RI matching (CUBIC-R+(M); Product No. T3740), <3 days
Microscopic observation
Related Products
T3740 Tissue-Clearing Reagent CUBIC-L [for delipidation and decoloring]| Numéro de produit | C3717 |
Condition de stockage
|
Refrigerated (0-10°C) |
| Condition à éviter | Heat Sensitive |
| Pictogramme |
|
| Mot de signal | Attention |
| Mentions de danger | H319 : Provoque une sévère irritation des yeux. |
| Conseils de prudence | P264 : Se laver la peau soigneusement après manipulation. P280 : Porter un équipement de protection des yeux/ du visage. P337 + P313 : Si l'irritation oculaire persiste: consulter un médecin. P305 + P351 + P338 : EN CAS DE CONTACT AVEC LES YEUX: Rincer avec précaution à l'eau pendant plusieurs minutes. Enlever les lentilles de contact si la victime en porte et si elles peuvent être facilement enlevées. Continuer à rincer. |
| N ° SH (import / export) (TCI-E) | 3822190090 |
La FDS demandée n'est pas disponible.
Nous contacter pour plus d'informations.
text.sds.search.errormsg.content.1.kishida
Les spécifications demandées ne sont pas disponibles.
Nous contacter pour plus d'informations.
text.specification.search.errormsg.content.1.kishida
Veuillez vérifier que le numéro de lot que vous avez saisi est correct. Il s'agit de 4 à 5 caractères alphanumériques avant le trait d'union. Veuillez vérifier soigneusement si O (alphabet) ou 0 (chiffre), "I (alphabet) ou 1 (chiffre) en particulier.
Si les informations sont correctes et que vous ne pouvez toujours pas voir le certificat demandé, veuillez nous contacter.
text.certificate.analysis.pdf.errormsg.content6.kishida
Un échantillon CoA pour ce produit n'est pas disponible pour le moment.
Le tableau analytique demandé n'est pas disponible. Nous sommes désolés pour ce désagrément.