text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Bitte wählen Sie die Menge aus.

CAS RN: 7681-65-4 | Produkte #: R0314

CuI (HPMC encapsulated)


New
Reinheit:
Synonyme
  • Copper(I) Iodide (HPMC encapsulated)
  • Cuprous Iodide (HPMC encapsulated)
Produktdokumente:
10EACH
€65.00
Kontaktieren Sie uns 12  

*In Belgien verfügbare Lagerbestände werden in 1 bis 3 Tagen geliefert.
*In Japan verfügbare Lagerbestände werden in 1 bis 2 Wochen geliefert. (unter Ausschluss von regulierten Artikeln und Trockeneislieferungen).


Ergänzende Produktinformation:

Contents (per one capsule)

  • CuI ca. 0.800 mmol

Uses of Reagent

  • Applicable to copper-catalyzed reactions due to a copper catalyst encapsulated in HPMC capsules

Soluble Solvents

  • Water, DMSO, DMF, 1,4-Dioxane (50°C), THF/Water mixture, 1,2-Dimethoxyethane/Water mixture

Related Product

  • C2163 Copper(I) Iodide

Artikel # R0314
Summenformel / Molekülmasse CuI = 190.45 
Physikalischer Zustand (20 °C) Solid
Lagerungstemperatur Room Temperature (Recommended in a cool and dark place, <15°C)
Unter Inertgas lagern Store under inert gas
Zu vermeidende Bedingungen Hygroscopic
CAS RN 7681-65-4
Spezifikation
Appearance White to Almost white capsule
Functionality test (conversion ratio) min.90.0 %
Eigenschaften
GHS
Piktogramm Pictogram Pictogram Pictogram Pictogram
Signalwort Gefahr
Gefahrenhinweise H302 : Gesundheitsschädlich bei Verschlucken.
H315 : Verursacht Hautreizungen.
H318 : Verursacht schwere Augenschäden.
H373 : Kann die Organe schädigen bei längerer oder wiederholter Exposition.
H317 : Kann allergische Hautreaktionen verursachen.
H335 : Kann die Atemwege reizen.
H410 : Sehr giftig für Wasserorganismen, mit langfristiger Wirkung.
Sicherheitshinweise P273 : Freisetzung in die Umwelt vermeiden.
P260 : Staub nicht einatmen.
P264 : Nach Gebrauch Haut gründlich waschen.
P280 : Schutzhandschuhe/ Augenschutz/ Gesichtsschutz tragen.
P391 : Verschüttete Mengen aufnehmen.
P305 + P351 + P338 + P310 : BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen.
Verwandte Gesetze:
Transportinformationen:
UN-Nummer UN3077
Klasse 9
Verpackungsgruppe (DOT-AIR) III
HS-Nr. (Import / Export) (TCI-E) 3822190090
Anwendung
TCI Practical Example: Goldberg Amination Using Capsule Reagents

TCI Practical Example: Goldberg Amination Using Capsule Reagents

Used Chemicals

Procedure

Copper(I) iodide (HPMC encapsulated) (one capsule) and 1,10-phenanthroline (HPMC encapsulated) (one capsule) were added to a solution of indole (93.7 mg, 800 µmol), 2-bromopyridine (164 mg, 1.04 mmol, 1.3 eq.) and cesium carbonate (521 mg, 1.60 mmol, 2.0 eq.) in DMSO (2.5 mL) at r.t. and the reaction mixture was stirred at 150 °C for 2 hours. After cooling to r.t., the solution was diluted with ethyl acetate (15 mL) and sat. Na2SO4 aq. (15 mL), and filtered through Celite pad and the filtrate was extracted with ethyl acetate (15 mL x 2). The organic layer was washed with 2 mol/L HCl (15 mL) and sat. NaHCO3 aq. (15 mL), dried over sodium sulfate and concentrated under reduced pressure. The crude product was purified by silica gel column chromatography (ethyl acetate:hexane = 10:1 - 5:1) to afford N-(2-pyridyl)indole (130 mg, 84% yield) as a pale-yellow oil.

Experimenter’s Comments

The reaction mixture was monitored by UPLC.
The material of the capsule is water-soluble HPMC (hydroxypropyl methylcellulose).
The capsule has the shape shown in Figure 1 and 1,10-phenanthroline (ca. 200 μmol) and copper(I) iodide (ca. 800 μmol) are encapsulated in each capsule, respectively.

Appearance of capsule
Figure 1. Appearance of capsule

The capsules dissolves in water or polar solvents as shown in Figure 2.
Capsule disintegrating
Figure 2. Capsule disintegrating
(left) Just after the capsule is put in, (right) 15 minutes after the capsule is put in

Analytical Data

N-(2-Pyridyl)-indole

1H NMR (400 MHz, CDCl3); δ 8.21 (d, 1H, J = 8.0 Hz), 7.85-7.81 (m, 1H), 7.37 (d, 1H, J = 4.0 Hz), 7.67 (d, 1H, J = 8.0 Hz), 7.51 (d, 1H, J = 8.0 Hz), 7.30(t, 1H, J = 8.0 Hz), 7.23-7.16 (m, 2H).

Lead Reference

Other References


Produktdokumente (Hinweis: Für einige Produkte sind keine Analysediagramme verfügbar.)
Sicherheitsdatenblatt (SDB)
Bitte wählen Sie Sprache.

Das angeforderte SDB ist nicht verfügbar.

Bitte Kontaktieren Sie uns für mehr Informationen.

Spezifikationsdokumenten
AZ & andere Zertifikate
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das Produkt mit der gesuchten Lotnummer wude eingestellt und die dazugehörige Dokumentation wird nicht mehr bereitgestellt. Bitte probieren Sie verschiedene Lotnummern für dieses Produkt aus.

Muster-AZ
Dies ist ein Muster-AZ und repräsentiert möglicherweise nicht eine kürzlich hergestellte Charge des Produkts.

Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.

Analytische Diagramme
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.

Das Produkt mit der gesuchten Lotnummer wude eingestellt und die dazugehörige Dokumentation wird nicht mehr bereitgestellt. Bitte probieren Sie verschiedene Lotnummern für dieses Produkt aus.

Andere Dokumente

Sitzungsstatus
Ihre Sitzung wird in 10 Minuten beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen. Minute beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen.

Deine Sitzung ist abgelaufen. Sie werden auf die Startseite weitergeleitet.