Published TCIMAIL newest issue No.200 | Product Document Searching Made Easy by 2D Code! | TCI Life Science News December 2025 | [TCIPracticalExample] Suzuki-Miyaura Coupling Using Encapsulated... | Various analytical charts can be searched on each product detail page and Product Document Search (The kinds of analytical charts differ by product)
Maximum quantity allowed is 999
请选择数量
CAS RN: 150993-62-7 | 产品编码: A5565
(R)-(+)-DBD-Pro-COCl [=(R)-(+)-4-(N,N-Dimethylaminosulfonyl)-7-(2-chloroformylpyrrolidin-1-yl)-2,1,3-benzoxadiazole] [HPLC Labeling Reagent for e.e. Determination]
纯度/分析方法: >90.0%(qNMR)
别名:
- (R)-(+)-DBD-Pro-COCl [=(R)-(+)-4-(N,N-二甲氨基磺酰基)-7-(2-氯甲酰四氢吡咯-1-基)-2,1,3-苯并恶二唑] [用于e.e.值测定的HPLC标记试剂]
- (R)-(+)-4-(N,N-二甲基氨基磺酰)-7-(2-氯甲酰吡咯烷-1-基)苯并呋咱
- (R)-(+)-4-(N,N-Dimethylaminosulfonyl)-7-(2-chloroformylpyrrolidin-1-yl)benzofurazan
- (R)-(+)-4-(N,N-Dimethylaminosulfonyl)-7-(2-chloroformylpyrrolidin-1-yl)-2,1,3-benzoxadiazole
产品文档:
技术规格
| Appearance | Light yellow to Yellow to Orange powder to crystal |
| Purity(HPLC) | min. 95.0 area% |
| Optical purity(LC) | min. 99.0 ee% |
| Purity(qNMR) | min. 90.0 % |
| Effect test of HPLC derivatization | Effective as labeling agent fo 2-Hexanol |
| NMR | confirm to structure |
物性(参考值)
| 比旋光度 [α]D | 44° (C=0.2,CHCl3) |
GHS
| 象形图 |
|
| 信号词 | Warning |
| 危险性说明 | H315 : Causes skin irritation. H319 : Causes serious eye irritation. |
| 防范说明 | P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ eye protection/ face protection. P302 + P352 : IF ON SKIN: Wash with plenty of water. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P362 + P364 : Take off contaminated clothing and wash it before reuse. P332 + P313 : If skin irritation occurs: Get medical advice/ attention. |
相关法规
运输信息
| HS编码* | 2935.90-000 |
应用
HPLC Labeling Reagent for Chiral Alcohols and Amines
The compound 1 is an HPLC fluorescence labeling reagent for optical purity determination, which easily reacts with optical active alcohols or amines to form the corresponding esters or amides, respectively. The resultant esters or amides are stable and can reach the detector without any decomposition under reversed and normal phase HPLC. An excellent chromatogram can be obtained by fluorescence detection at the excitation and emission wavelength of 450 nm and 560 nm, respectively. And the diastereomers derived from racemic alcohol and 1 can be separated by HPLC (The separation factor α: 2-hexanol = 1.2). Since no racemization can occur with derivatization reaction, it is possible to change an elution order of the labeled diastereomeres by selecting the enantiomer [(S)-(-)-DBD-Pro-COCl] of 1. The detection limit for the alcohols is sub-picomol. A highly sensitive analysis can be done by peroxyoxalate chemiluminescence detection.

Application example:
[Secondary alcohols] 1)
Add 1 mL of 10 mM labeling reagent 1 / dry benzene solution, 1 mL of 2 mM alcholol / dry benzene (containing 1% of pyridine) solution to a vessel. Close the cap of the reaction vessel and incubate the mixture at 80 °C for 3 h. After cooling to room temperature, excess of 1 is removed by liquid-liquid extraction (e.g. washing with 5% NaHCO3 solution) or solid phase extraction. Use the resultant as an HPLC sample solution.
[Secondary alcohols] 1)
Add 1 mL of 10 mM labeling reagent 1 / dry benzene solution, 1 mL of 2 mM alcholol / dry benzene (containing 1% of pyridine) solution to a vessel. Close the cap of the reaction vessel and incubate the mixture at 80 °C for 3 h. After cooling to room temperature, excess of 1 is removed by liquid-liquid extraction (e.g. washing with 5% NaHCO3 solution) or solid phase extraction. Use the resultant as an HPLC sample solution.
TCI Products Pamphlet
HPLC Labeling Reagents ( PDF 10MB )
HPLC Labeling Reagents ( PDF 10MB )
References
- 1)T. Toyo’oka, M. Ishibashi, T. Terao, Analyst 1993, 118, 759.

- 2)Tokyo Kasei Kogyo Co. Ltd., Jpn. Kokai Tokkyo Koho 94 184141, 1994.
PubMed Literature
技术文章
产品文档 (部分产品的分析图谱无法提供,敬请谅解。)
