Ergänzende Produktinformation:

Contents (per one capsule)

  • 2,2'-Bipyridyl ca. 0.500 mmol

Uses of Reagent

  • Applicable to copper-catalyzed reactions due to a ligand encapsulated in HPMC capsules

Soluble Solvents

  • Water, DMSO, DMF, 1,4-Dioxane (50°C), THF/Water mixture, 1,2-Dimethoxyethane/Water mixture

Related Product

  • B0468 2,2'-Bipyridyl

Artikel # R0310
Summenformel / Molekülmasse C__1__0H__8N__2 = 156.19 
Physikalischer Zustand (20 °C) Solid
Lagerungstemperatur Room Temperature (Recommended in a cool and dark place, <15°C)
Unter Inertgas lagern Store under inert gas
Zu vermeidende Bedingungen Hygroscopic
CAS RN 366-18-7
Spezifikation
Appearance White to Almost white capsule
Functionality test (conversion ratio) min.90.0 %
Eigenschaften
GHS
Piktogramm Pictogram Pictogram
Signalwort Gefahr
Gefahrenhinweise H301 + H311 : Giftig bei Verschlucken oder Hautkontakt.
H373 : Kann die Organe schädigen bei längerer oder wiederholter Exposition.
H341 : Kann vermutlich genetische Defekte verursachen.
Sicherheitshinweise P260 : Staub nicht einatmen.
P201 : Vor Gebrauch besondere Anweisungen einholen.
P264 : Nach Gebrauch Haut gründlich waschen.
P280 : Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz/ Gehörschutz Tragen.
P301 + P310 + P330 : BEI VERSCHLUCKEN: Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen. Mund ausspülen.
P302 + P352 + P312 : BEI BERÜHRUNG MIT DER HAUT: Mit viel Wasser waschen. Bei Unwohlsein GIFTINFORMATIONSZENTRUM/Arzt anrufen.
Verwandte Gesetze:
Transportinformationen:
UN-Nummer UN2811
Klasse 6.1
Verpackungsgruppe (DOT-AIR) III
HS-Nr. (Import / Export) (TCI-E) 3822190090
Anwendung
TCI Practical Example: Goldberg Amination Using Capsule Reagents

TCI Practical Example: Goldberg Amination Using Capsule Reagents

Used Chemicals

Procedure

Copper(I) iodide (HPMC encapsulated) (one capsule) and 2,2’-bipyridyl (HPMC encapsulated) (one capsule) were added to a solution of indole (93.7 mg, 800 µmol), 2-bromopyridine (164 mg, 1.04 mmol, 1.3 eq.) and cesium carbonate (521 mg, 1.60 mmol, 2.0 eq.) in DMSO (2.5 mL) at room temperature and the reaction mixture was stirred at 150 °C for 5 hours. After cooling to room temperature, the solution was diluted with ethyl acetate (15 mL) and sat. Na2SO4 aq. (15 mL), and filtered through Celite pad. The filtrate was extracted with ethyl acetate (15 mL x 2) and the organic layer was dried over sodium sulfate and concentrated under reduced pressure. The crude product was purified by silica gel column chromatography (ethyl acetate:hexane = 1:10 - 1:5) to afford N-(2-pyridyl)indole (71 mg, 46% yield) as a pale-yellow oil.

Experimenter’s Comments

The reaction mixture was monitored by UPLC.
The material of the capsule is water-soluble HPMC (hydroxypropyl methylcellulose).
The capsule has the shape shown in Fig. 1 and 2,2’-bipyridyl (ca. 500 μmol) and copper(I) iodide (ca. 800 μmol) are encapsulated in each capsule, respectively.

Appearance of capsule
Fig. 1. Appearance of the capsule
The capsule dissolves in water or polar solvent as shown in Fig. 2.
Appearance of capsule
Fig. 2. Capsule disintegrating
(left) Immediately after the addition of the capsule,
(right) 15 minutes after the addition of the capsule.

Analytical Data

N-(2-Pyridyl)indole

1H NMR (400 MHz, CDCl3); δ 8.21 (d, 1H, J = 8.0 Hz), 7.85-7.81 (m, 1H), 7.37 (d, J = 4.0 Hz, 1H), 7.67 (d, J = 8.0 Hz, 1H), 7.51 (d, J = 8.0 Hz, 1H), 7.30 (t, J = 8.0 Hz, 1H), 7.23-7.16 (m, 2H).

Lead Reference

Other Reference


Produktdokumente (Hinweis: Für einige Produkte sind keine Analysediagramme verfügbar.)
Sicherheitsdatenblatt (SDB)
Bitte wählen Sie Sprache.

Das angeforderte SDB ist nicht verfügbar.

Bitte Kontaktieren Sie uns für mehr Informationen.

Spezifikationsdokumenten
AZ & andere Zertifikate
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Die gesuchte Lotnummer ist nicht mehr verfügbar und die zugehörige Dokumentation wird nicht mehr bereitgestellt. Bitte versuchen Sie es mit einer anderen Lotnummer für dieses Produkt.

Muster-AZ
Dies ist ein Muster-AZ und repräsentiert möglicherweise nicht eine kürzlich hergestellte Charge des Produkts.

Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.

Analytische Diagramme
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.

Die gesuchte Lotnummer ist nicht mehr verfügbar und die zugehörige Dokumentation wird nicht mehr bereitgestellt. Bitte versuchen Sie es mit einer anderen Lotnummer für dieses Produkt.

Andere Dokumente

Sitzungsstatus
Ihre Sitzung wird in 10 Minuten beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen. Minute beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen.

Deine Sitzung ist abgelaufen. Sie werden auf die Startseite weitergeleitet.

Beim Wechsel der Region werden Sie von Ihrer aktuellen Sitzung abgemeldet. Möchten Sie fortfahren?