Published TCIMAIL newest issue No.200 | Product Document Searching Made Easy by 2D Code! | TCI Chemistry News November 2025 | [Product Highlights] Catechol-containing Methacrylate Monomer for... | Various analytical charts can be searched on each product detail page and Product Document Search (The kinds of analytical charts differ by product)
Maximum quantity allowed is 999
CAS RN: | 제품번호: R0275
Reagents for Suzuki-Miyaura Cross-Coupling Reactions [Pd(dppf)Cl2·CH2Cl2, Cs2CO3] (HPMC encapsulated)
순도/분석 방법:
- Pd(dppf)Cl2·CH2Cl2 ca. 0.03 mmol/capsule, Cs2CO3 ca. 0.7 mmol/capsule (HPMC encapsulated)
•본건의 원가격은 한국 대리점의 예상 판매가격입니다.자세한 정보가 필요하시면 연락해 주십시오.( SEJIN CI Co., Ltd. (한국총대리점) 전화 : 02-2655-2480 이메일 : sales@sejinci.co.kr)
•보관 조건은 예고없이 변경 될 수 있습니다. 제품 보관 조건의 최신 자료는 홈페이지에 기재되어 있으니 양해 부탁드립니다.
제품보충정보:
Contents (per one capsule)
- Pd(dppf)Cl2·CH2Cl2 : ca. 0.03 mmol
- Cs2CO3 : ca. 0.7 mmol
Directions for Use
- Each capsule contains all reagents for a single use on 0.60 mmol scale Suzuki-Miyaura Cross-Coupling Reactions. Typical condition: 0.60 mmol of aryl halide and 1.5 equiv of boronic acid in THF/water (4:1) (0.30 M) at 100 °C.
(Reference: J. Org. Chem. 2021, 86, 1357.)
Related Products
- B2064 [1,1'-Bis(diphenylphosphino)ferrocene]palladium(II) Dichloride Dichloromethane Adduct (= Pd(dppf)Cl2·CH2Cl2)
- C2160 Cesium Carbonate (= Cs2CO3)
| 제품번호 | R0275 |
| 물리적 상태 (20 ℃) | Solid |
보관 조건
|
Refrigerated (0-10°C) |
| 불활성 가스 하에서 보관 | Store under inert gas |
| 피해야 할 조건 | Air Sensitive |
| Appearance | White to Light yellow to Light orange capsule |
| Functionality test (conversion ratio) | min. 90.0 % |
| 픽토그램 |
|
| 신호 워드 | Danger |
| 위험물 및 유해 등록 | H318 : Causes serious eye damage. H361 : Suspected of damaging fertility or the unborn child. H373 : May cause damage to organs through prolonged or repeated exposure. |
| 주의 사항 | P501 : Dispose of contents/ container to an approved waste disposal plant. P260 : Do not breathe dust/ fume/ gas/ mist/ vapors/ spray. P202 : Do not handle until all safety precautions have been read and understood. P201 : Obtain special instructions before use. P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection. P308 + P313 : IF exposed or concerned: Get medical advice/ attention. P305 + P351 + P338 + P310 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor. P405 : Store locked up. |
| HS 번호* | 3822.19-000 |
-
Used Chemicals
-
Procedure
-
Reagents for Suzuki-Miyaura Cross-Coupling Reactions (one capsule) was added to a solution of 2-acetamido-5-bromo-4-methylpyridine (137 mg, 0.60 mmol) and phenylboronic acid (110 mg, 0.90 mmol, 1.5 eq.) in THF/H2O (4:1, 2 mL) at r.t. and the reaction mixture was stirred at 100 °C for 2 hours. The solution was then filtered through Celite pad and the filtrate was diluted with sat. Na2SO4 aq. (15 mL). The aqueous layer was extracted with ethyl acetate (15 mL x 2) and the organic layer was washed with water (15 mL) and brine (15 mL), dried over sodium sulfate and concentrated under reduced pressure. The crude product was purified by silica gel chromatography (ethyl acetate:hexane = 2:1 - 1:4) and then further purified by reversed-phase silica gel chromatography (water:acetonitrile = 95:5 - 40:60) to afford 2-acetamido-4-methyl-5-phenylpyridine (122 mg, 90% yield) as a white solid.
-
Experimenter’s Comments
-
The reaction mixture was monitored by GC.
The shape of the capsule is like below image and Pd(dppf)Cl2·CH2Cl2 (ca. 0.03 mmol) and Cs2CO3 (ca. 0.7 mmol) are encapsulated in each capsule.
The material of the capsule is water-soluble HPMC (hydroxypropyl methylcellulose).
Since it was difficult to remove the starting material by the normal phase silica gel column purification, so the reverse-phase column purification was performed.
-
Analytical Data
-
2-Acetamido-4-methyl-5-phenylpyridine
1H NMR (400 MHz, CDCl3); δ 9.24-9.06 (brs, 1H), 8.16 (s, 1H), 8.10 (s, 1H), 7.46-7.36 (m, 3H), 7.30-7.29 (m, 2H), 2.32 (s, 3H), 2.21 (s, 3H).
-
Lead Reference
-
- Reagent and Catalyst Capsules: A Chemical Delivery System for Reaction Screening and Parallel Synthesis
-
Other Reference
-
- HPMC: A Biomass-Based Semisynthetic Sustainable Additive Enabling Clean and Fast Chemistry in Water
SDS
요청한 SDS를 사용할 수 없습니다.
번거롭게 해드려 죄송하지만 이 양식 보다 문의 해주십시오.
규격표
시험성적서, 각종 증명서
샘플 시험성적서
본 제품의 샘플시험성적서는 현재 준비되어 있지 않습니다.
분석 차트
죄송합니다만 찾으시는 분석차트는 없습니다.