Published TCIMAIL newest issue No.200
Maximum quantity allowed is 999
CAS RN: 524-95-8 | Numéro de produit: D0281
2-Aminoethyl Diphenylborinate
Pureté: >98.0%(T)(HPLC)
- (2-Aminoethoxy)diphenylborane
- Diphenylborinic Acid 2-Aminoethyl Ester
*Stock disponible en Belgique : Expédition le jour même
*Stock disponible au Japon : Veuillez consulter la simulation d'expédition pour une estimation des délais d'expédition (hors articles réglementés et expédition avec Carboglace)
| Numéro de produit | D0281 |
Pureté / Méthode d'analyse
|
>98.0%(T)(HPLC) |
| Formule moléculaire / poids moléculaire | C__1__4H__1__6BNO = 225.10 |
| Etat physique (20 ° C) | Solid |
Condition de stockage
|
Room Temperature (Recommended in a cool and dark place, <15°C) |
| Stocker sous gaz inerte | Store under inert gas |
| Condition à éviter | Light Sensitive,Moisture Sensitive |
| CAS RN | 524-95-8 |
| Numéro de registre de Reaxys | 2942273 |
| Identifiant de la substance PubChem | 87566979 |
| SDBS | 7335 |
| Numéro MDL | MFCD00014823 |
| Appearance | White to Almost white powder to crystal |
| Purity(HPLC) | min. 98.0 area% |
| Purity(Nonaqueous Titration) | min. 98.0 % |
| Melting point | 189.0 to 194.0 °C |
| Solubility in Methanol | almost transparency |
| Point de fusion | 190 °C |
| Solubilité (soluble dans) | Methanol |
| Pictogramme |
|
| Mot de signal | Attention |
| Mentions de danger | H315 : Provoque une irritation cutanée. H319 : Provoque une sévère irritation des yeux. |
| Conseils de prudence | P264 : Se laver la peau soigneusement après manipulation. P280 : Porter des gants de protection/ un équipement de protection des yeux/ du visage. P302 + P352 : EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment à l’eau. P337 + P313 : Si l'irritation oculaire persiste: consulter un médecin. P362 + P364 : Enlever les vêtements contaminés et les laver avant réutilisation. P332 + P313 : En cas d'irritation cutanée: consulter un médecin. |
| Numéros CE | 208-366-5 |
| RTECS # | ED6150000 |
| N ° SH (import / export) (TCI-E) | 2931900090 |

-
Used Chemicals
-
Procedure
-
To a solution of methyl α-L-fucopyranoside (392 mg, 2.2 mmol, 1.1 equiv), silver(I) oxide (463 mg, 2.0 mmol, 1.0 equiv) and 2-aminoethyl diphenylborinate (45 mg, 0.2 mmol, 10 mol%) in acetonitrile (23 mL) was added 2,3,4,6-tetra-O-acetyl-α-D-glucopyranosyl bromide (822 mg, 2.0 mmol, 1 equiv) at r.t. and the mixture was stirred for 4 hours. The reaction mixture was filtered through celite pad and washed with dichloromethane (30 mL). The solvent was removed under reduced pressure and the residue was purified by column chromatography (ethyl acetate:hexane = 0:1 - 3:1 on silica gel), to give 1 as a white amorphous (914 mg, 90%).
-
Experimenter’s Comments
-
The reaction mixture was monitored by TLC (ethyl acetate, Rf = 0.51).
The color of the reaction mixture turned from black to gray as the reaction proceeds.
-
Analytical Data(Compound 1)
-
1H NMR (400 MHz, CDCl3); δ 5.23 (t, J = 9.5 Hz, 1H), 5.07 (t, J = 9.5 Hz, 1H), 5.04 (dd, J = 9.5, 7.8 Hz, 1H), 4.83 (d, J = 3.8 Hz, 1H), 4.68 (d, J = 7.8 Hz, 1H), 4.25 (dd, J = 12.2, 2.7 Hz, 1H), 4.17 (dd, J = 12.2, 5.1 Hz, 1H), 3.99 (dd, J = 10.0, 3.8 Hz, 1H), 3.95 (brq, J = 6.8 Hz, 1H), 3.83 (dd, J = 10.0, 3.5 Hz, 1H), 3.76 (ddd, J = 10.0, 5.1, 2.7 Hz, 1H), 3.72 (m, 1H), 3.43 (s, 3H), 3.14 (d, J = 3.8 Hz, 1H), 2.27 (brs, 1H), 2.10 (s, 3H), 2.07 (s, 3H), 2.04 (s, 3H), 2.02 (s, 3H), 1.31 (d, J = 6.8 Hz, 3H).
-
Lead Reference
-
- Regioselective Activation of Glycosyl Acceptors by a Diarylborinic Acid-Derived Catalyst
-
Other References
-
- Boronic Acid-Catalyzed Regioselective Koenigs–Knorr-Type Glycosylation
References
- 2APB, 2-Aminoethoxydiphenyl Borate, a Membrane-Penetrable Modulator of Ins(1,4,5)P3-Induced Ca2+ Release
- 2-Aminoethoxydiphenyl borate (2-APB) is a reliable blocker of store-operated Ca2+ entry but an inconsistent inhibitor of InsP3-induced Ca2+ release
- 2-Aminoethoxydiphenyl borate (2-APB) antagonises inositol 1,4,5-trisphosphate-induced calcium release, inhibits calcium pumps and has a use-dependent and slowly reversible action on store-operated calcium entry channels
Fiche de sécurité (FDS)
La FDS demandée n'est pas disponible.
Nous contacter pour plus d'informations.
Spécifications
CoA et autres Certificats
Exemple de CoA
Un échantillon CoA pour ce produit n'est pas disponible pour le moment.
Graphiques analytiques