Published TCIMAIL newest issue No.201
Maximum quantity allowed is 999
CAS RN: 2446-83-5 | Produkte #: A1246
Diisopropyl Azodicarboxylate (40% in Toluene, ca. 1.9mol/L)
Reinheit:
- Azodicarboxylic Acid Diisopropyl Ester (40% in Toluene, ca. 1.9mol/L)
- DIAD (40% in Toluene, ca. 1.9mol/L)
*Lagerbestand in Belgien: Versand am selben Tag
*Lagerbestand in Japan: Bitte prüfen Sie die Versandsimulation für voraussichtliche Lieferzeiten. (ausgenommen regulierte Produkte und Trockeneissendungen)
Ergänzende Produktinformation:
This product cannot be shipped to Russia and Turkey.
| Artikel # | A1246 |
| Summenformel / Molekülmasse | C__8H__1__4N__2O__4 = 202.21 |
| Physikalischer Zustand (20 °C) | Liquid |
Lagerungstemperatur
|
Refrigerated (0-10°C) |
| Zu vermeidende Bedingungen | Light Sensitive,Heat Sensitive |
| CAS RN | 2446-83-5 |
| Reaxys Registrierungsnummer | 5262252 |
| MDL-Nummer | MFCD00008875 |
| Appearance | Light yellow to Amber to Dark green clear liquid |
| Concentration(Iodometric titration) | 40.0 to 44.0 w/w% |
| NMR | confirm to structure |
| Spezifisches Gewicht (20/20) | 0.94 |
| Brechungsindex | 1.47 |
| Piktogramm |
|
| Signalwort | Gefahr |
| Gefahrenhinweise | H312 + H332 : Gesundheitsschädlich bei Hautkontakt oder Einatmen. H315 : Verursacht Hautreizungen. H319 : Verursacht schwere Augenreizung. H370 : Schädigt die Organe. H372 : Schädigt die Organe bei längerer oder wiederholter Exposition. H335 : Kann die Atemwege reizen. H361d : Kann vermutlich das Kind im Mutterleib schädigen. H336 : Kann Schläfrigkeit und Benommenheit verursachen. H304 : Kann bei Verschlucken und Eindringen in die Atemwege tödlich sein. H225 : Flüssigkeit und Dampf leicht entzündbar. |
| Sicherheitshinweise | P260 : Nebel oder Dampf nicht einatmen. P210 : Von Hitze, heißen Oberflächen, Funken, offenen Flammen und anderen Zündquellen fernhalten. Nicht rauchen. P280 : Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz/ Gehörschutz Tragen. P370 + P378 : Bei Brand: Trockensand, Löschpulver oder alkoholbeständigen Schaum zum Löschen verwenden. P331 : KEIN Erbrechen herbeiführen. P308 + P311 : BEI Exposition oder falls betroffen: GIFTINFORMATIONSZENTRUM/Arzt anrufen. P301 + P310 : BEI VERSCHLUCKEN: Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen. |
| EC-Nummern | 219-502-8 |
| UN-Nummer | UN1993 |
| Klasse | 3 |
| Verpackungsgruppe (DOT-AIR) | II |
| HS-Nr. (Import / Export) (TCI-E) | 2927000090 |
-
Used Chemicals
-
Procedure
-
To a solution of triphenylphosphine (0.88 g, 3.4 mmol), 5-mercapto-1-phenyl-1H-tetrazole (0.79 g 4.4 mmol), 3-phenylpropan-1-ol (0.30 g, 2.2 mmol) in anhydrous tetrahydrofuran (22 mL) was added DIAD (40% in toluene, 2.1 mL, 4.0 mmol) at 0 °C and the mixture was stirred at rt for 1 hour. The solution was dropped into water (40 mL). The mixture was extracted with ethyl acetate (40 mL x 3), and organic phase was dried over sodium sulfate and filtered. The solvent was removed under reduced pressure and the residue was purified by column chromatography (ethyl acetate:hexane = 1:9 on silica gel) to give 1 (0.68 g, quant) as a white solid.
-
Experimenter’s Comments
-
The reaction mixture was monitored by TLC (ethyl acetate:hexane = 1:9, Rf = 0.29).
-
Analytical Data
-
Compound 1
1H NMR (400 MHz, CDCl3); δ 7.63-7.50 (m, 5H), 7.35-7.26 (m, 2H), 7.23-7.14 (m, 3H), 3.40 (t, J = 7.0 Hz, 2H), 2.79 (t, J = 7.6 Hz, 2H), 2.18 (quin, J = 7.3 Hz, 2H)
-
Lead Reference
-
- One-Pot Substitution of Aliphatic Alcohols Mediated by Sulfuryl Fluoride
Dokumente
Sicherheitsdatenblatt (SDB)
Das angeforderte SDB ist nicht verfügbar.
Bitte Kontaktieren Sie uns für mehr Informationen.
text.sds.search.errormsg.content.1.kishida
Spezifikationsdokumenten
Die angeforderten Spezifikationen sind nicht verfügbar.
Bitte Kontaktieren Sie uns für mehr Informationen.
text.specification.search.errormsg.content.1.kishida
AZ & andere Zertifikate
Bitte überprüfen Sie, ob die von Ihnen eingegebene Chargennummer korrekt ist. Sie besteht aus 4-5 alphanumerischen Zeichen vor dem Bindestrich. Bitte prüfen Sie sorgfältig, ob O (Alphabet) oder 0 (Zahl), "I (Alphabet) oder 1 (Zahl) im Besonderen.
Wenn Ihre Eingabe korrekt ist und Sie dennoch das Zerifikat nicht angezeigt bekommen, kontaktieren Sie uns bitte.
text.certificate.analysis.pdf.errormsg.content6.kishida
Muster-AZ
Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.
Analytische Diagramme
Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.