Maximum quantity allowed is 999
Merci de sélectionner la quantité
CAS RN: | Numéro de produit: B5944
Bovine Serum Albumin Maleimide Conjugate (1mg×3)
Pureté:
Synonymes
- BSA Maleimide (1mg×3)
Documents de produit:
*Stock disponible en Belgique : Expédition le jour même
*Stock disponible au Japon : Veuillez consulter la simulation d'expédition pour une estimation des délais d'expédition (hors articles réglementés et expédition avec Carboglace)
Informations supplémentaires sur le produit:
Product Information
- Volume/Quantity : 1.0 mg x 3 vial
- Conjugation : Purified Bovine Serum Albumin (BSA) was conjugated to Sulfo-SMCC (Product No. S0883).
- Product Form : BSA Maleimide Conjugate. Lyophilized in 10 mM sodium phosphate, 0.115 mM NaCl, 1 mM EDTA, 40 mM sucrose, pH 6.6.
- Preservative : None
Description
- BSA Maleimide Conjugate is designed to facilitate the conjugation of the BSA to proteins, peptides and ligands that contain free sulfhydryl (-SH) groups. Activated BSA contains 15–35 maleimide groups for each BSA molecule. BSA is conjugated to haptens and typically used as a non-relevant carrier in an ELISA for measuring specific anti-hapten antibody titers.
Protocol
-
- Firstly return the vial to room temperature.
- Reconstitute the contents of the vial with 100 μL of buffer or water to obtain a 10 mg/mL solution of BSA Maleimide.
Note: Do not vortex or heat the BSA Maleimide. - Dissolve 1 mg of a thiol-containing molecule in 100-250 μL of buffer or water. (4-10 mg/mL)
Note: In case of thiol-containing molecules insoluble in buffer or water, DMSO may be used for solubilization (caution: less than 30% DMSO in the final reaction solution). We recommend that the thiol-containing molecule is dissolved in the pH range 6.5-7.5 buffer. 0.1 M sodium phosphate, 0.15 M NaCl, 0.1 M EDTA at pH 7.2 is commonly employed. Maleimides react with sulfhydryls at pH 6.5-7.5 to form stable thioether bonds. EDTA may help to prevent metal catalysed oxidation of thiols. For complete and efficient conjugation, the BSA Maleimide should mix with excess ratio of thiol-containing molecule. Alternatively, if an excess of thiol-containing molecule is not available, it is better to add a sulfhydryl-containing compound, such as cysteine, for quench remaining active maleimide groups. - Immediately mix the thiol-containing molecule and BSA Maleimide solutions and allow them to react for 2 hours at room temperature.
- If desired, desalt, dialyze or purify the conjugate.
Storage
- Store at −20 °C to −80 °C (Preferably at −80 °C). Reconstitute this reagent immediately before use. Do not prepare stock solutions for storage. Discard any unused reconstituted reagent.
Related Products
- H1621 Horseradish Peroxidase Maleimide Conjugate (0.5mg×3)
- H1746 Horseradish Peroxidase NHS Ester Conjugate (0.2mg×3)
- T3531 Streptavidin Maleimide Conjugate
- S0883 Sulfo-SMCC Sodium Salt
| Numéro de produit | B5944 |
| Etat physique (20 ° C) | Solid |
Condition de stockage
|
Frozen (-80°C) |
| Condition à éviter | Heat Sensitive |
Spécifications
| Appearance | White to Brown to Dark green powder to crystal |
| Molar Ratio Maleimido | 15-35 moles of maleimide per mole of BSA |
Propriétés
SGH
Lois connexes:
Informations de transport:
| N ° SH (import / export) (TCI-E) | 3502909000 |
Documents de produit (Note : Pour certains produits, les tableaux analytiques ne sont pas disponibles.)
Fiche de sécurité (FDS)
S'il vous plaît sélectionnez la langue.
La FDS demandée n'est pas disponible.
Nous contacter pour plus d'informations.
Spécifications
CoA et autres Certificats
Veuillez remplir le numéro de lot
Le numéro de lot saisi est incorrect. Veuillez saisir uniquement 4-5 caractères alphanumériques avant le trait d'union.
Exemple de CoA
Il s'agit d'un échantillon CoA qui peut ne pas représenter un lot récemment fabriqué du produit.
Un échantillon CoA pour ce produit n'est pas disponible pour le moment.
Graphiques analytiques
Veuillez remplir le numéro de lot
Le numéro de lot saisi est incorrect. Veuillez saisir uniquement 4-5 caractères alphanumériques avant le trait d'union.
Le tableau analytique demandé n'est pas disponible. Nous sommes désolés pour ce désagrément.