text.skipToContent text.skipToNavigation

Maximum quantity allowed is 999

Bitte wählen Sie die Menge aus.

CAS RN: 878376-35-3 | Produkte #: P2398

Pyridine-2-sulfonyl Fluoride


Reinheit: >98.0%(GC)(T)
Synonyme
  • PyFluor
Dokumente:
5G
€ 209,00
1   ≥40 

*In Belgien verfügbare Lagerbestände werden in 1 bis 3 Tagen geliefert.
*In Japan verfügbare Lagerbestände werden in 1 bis 2 Wochen geliefert. (unter Ausschluss von regulierten Artikeln und Trockeneislieferungen).


Artikel # P2398
Reinheit / Analysenmethode >98.0%(GC)(T)
Summenformel / Molekülmasse C__5H__4FNO__2S = 161.15 
Physikalischer Zustand (20 °C) Solid
Lagerungstemperatur Refrigerated (0-10°C)
Unter Inertgas lagern Store under inert gas
Zu vermeidende Bedingungen Moisture Sensitive,Heat Sensitive
CAS RN 878376-35-3
Reaxys Registrierungsnummer 10151877
PubChem-Stoff-ID 354333991
MDL-Nummer

MFCD09265513

Spezifikation
Appearance White to Almost white powder to lump
Purity(GC) min. 98.0 %
Purity(Neutralization titration) min. 98.0 %
NMR confirm to structure
Eigenschaften
Schmelzpunkt 26 °C
Flammpunkt 96 °C
GHS
Piktogramm Pictogram
Signalwort Gefahr
Gefahrenhinweise H314 : Verursacht schwere Verätzungen der Haut und schwere Augenschäden.
H290 : Kann gegenüber Metallen korrosiv sein.
Sicherheitshinweise P260 : Staub nicht einatmen.
P280 : Schutzhandschuhe/ Schutzkleidung/ Augenschutz/ Gesichtsschutz/ Gehörschutz Tragen.
P303 + P361 + P353 : BEI BERÜHRUNG MIT DER HAUT (oder dem Haar): Alle kontaminierten Kleidungsstücke sofort ausziehen. Haut mit Wasser abwaschen.
P301 + P330 + P331 : BEI VERSCHLUCKEN: Mund ausspülen. KEIN Erbrechen herbeiführen.
P304 + P340 + P310 : BEI EINATMEN: Die Person an die frische Luft bringen und für ungehinderte Atmung sorgen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen.
P305 + P351 + P338 + P310 : BEI KONTAKT MIT DEN AUGEN: Einige Minuten lang behutsam mit Wasser spülen. Eventuell vorhandene Kontaktlinsen nach Möglichkeit entfernen. Weiter spülen. Sofort GIFTINFORMATIONSZENTRUM/Arzt anrufen.
Verwandte Gesetze:
Transportinformationen:
UN-Nummer UN3261
Klasse 8
Verpackungsgruppe (DOT-AIR) II
HS-Nr. (Import / Export) (TCI-E) 2933399990
Anwendung
TCI Practical Example: Fluorination of an Alcohol Using PyFluor

TCI Practical Example: Fluorination of an Alcohol Using PyFluor

Used Chemicals

Procedure

A solution of PyFluor (513 mg, 3.19 mmol) in dry toluene (3.6 mL) was added to a solution of 2,3-O-isopropylidene-D-ribonic γ-lactone (500 mg, 2.66 mmol) and DBU (0.79 mL, 5.31 mmol) in toluene (3.0 mL) at 0 °C, and the solution was stirred at room temperature for one day. The reaction mixture was quenched with water (10 mL) and the aqueous layer was extracted with ethyl acetate (3 x 5 mL). The combined organic layer was washed with sat. NH4Cl aq. and brine, dried over anhydrous sodium sulfate and filtered. The solvent was removed under reduced pressure and the residue was purified by column chromatography (ethyl acetate:hexane = 0:100 - 15:85 on silica gel) to give the fluorinated compound 1 as a white solid (309 mg, 61% yield.).

Experimenter’s Comments

The reaction mixture was monitored by TLC (ethyl acetate:hexane = 1:2, Rf = 0.33).
It was easy to weigh PyFluor after melting PyFluor by heating with hot water bath because the melting point is 26 °C.

Analytical Data

Fluorinated Compound 1

1H NMR (270 MHz, DMSO-d6); δ 4.94-4.74 (m, 4H), 4.64 (ddd, J = 3.0, 10.8, 27.8 Hz, 1H), 1.37 (s, 3H), 1.33 (s, 3H).

Lead Reference


Anwendung
PyFluor: A Stable Deoxyfluorinating Agent

Experimental procedure: A vial is charged sequentially with substrate (1.0 mmol), toluene (1 mL, 1.0 mol/L), PyFluor (177 mg, 1.1 eq.), and DBU (300 µL, 2 eq.). PyFluor is dispensed as a liquid (m.p. 23 – 26 °C). The mixture is stirred at room temperature for 48 hours under ambient atmosphere. Occasionally, an exotherm is observed following addition of base, corresponding to sulfonate ester formation. Reaction progress is accompanied by formation of pale yellow to dark orange precipitates. Products are isolated by column chromatography.

References


PubMed Literatur


Artikel / Broschüren

Dokumente (Hinweis: Für einige Produkte sind keine Analysediagramme verfügbar.)
Sicherheitsdatenblatt (SDB)
Bitte wählen Sie Sprache.

Das angeforderte SDB ist nicht verfügbar.

Bitte Kontaktieren Sie uns für mehr Informationen.

Spezifikationsdokumenten
AZ & andere Zertifikate
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das Produkt mit der gesuchten Chargennummer wurde abgekündigt und es ist keine entsprechende Dokumentation verfügbar.

Muster-AZ
Dies ist ein Muster-AZ und repräsentiert möglicherweise nicht eine kürzlich hergestellte Charge des Produkts.

Ein Muster-AZ für dieses Produkt ist zur Zeit nicht verfügbar.

Analytische Diagramme
Bitte geben Sie die Lotnummer ein Falsche Chargennummer wurde eingegeben. Bitte geben Sie nur 4-5 alphanumerische Zeichen vor dem Bindestrich ein.

Das angeforderte Analysediagramm ist nicht verfügbar. Wir entschuldigen uns für die Unannehmlichkeiten.

Das Produkt mit der gesuchten Chargennummer wurde abgekündigt und es ist keine entsprechende Dokumentation verfügbar.

Andere Dokumente

Sitzungsstatus
Ihre Sitzung wird in 10 Minuten beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen. Minute beendet. Sie werden nach dem Ablauf der Sitzung auf die Startseite umgeleitet. Bitte klicken Sie auf die Schaltfläche, um die Sitzung auf derselben Seite fortzusetzen.

Deine Sitzung ist abgelaufen. Sie werden auf die Startseite weitergeleitet.