Sign up for free ground shipping on all website orders, no minimum required, and get exclusive coupons!
Maximum quantity allowed is 999
CAS RN: | Product Number: D6539
DiO Solution [for Cell Membrane Staining]
![DiO Solution [for Cell Membrane Staining] Chemical Structure of DiO Solution [for Cell Membrane Staining]](/medias/Tci-440-D6539.jpg?context=bWFzdGVyfHJvb3R8MTk0MzJ8aW1hZ2UvanBlZ3xhR0U0TDJneFl5ODVOakF3TVRFMU9UTXpNakUwTDFSamFTMDBOREJmUkRZMU16a3VhbkJufDJjMjA4YWRlNjcxMjdjNGI4NWMwMWE1NWZiZjFmODYxNjY0NWUxY2Y0OWQwYTRjZDQzYmExMGI2ZGFjZjVhZTY)
New
Purity:
Size | Unit Price | Philadelphia, PA | Portland, OR | Japan* | Quantity |
---|---|---|---|---|---|
1ML |
$180.00
|
Contact Us | Contact Us | 15 |
|
* Items in stock locally ship in 1-2 business days. Items from Japan stock are able to ship from a US warehouse within 2 weeks. Please contact TCI for lead times on items not in stock. Excludes regulated items and items that ship on ice.
* To send your quote request for bulk quantities, please click on the "Request Quote" button. Please note that we cannot offer bulk quantities for some products.
*TCI frequently reviews storage conditions to optimize them. Please note that the latest information on the storage temperature for the products is described on our website.
Supplemental Product Information:
Product Information
- Concentration : 1 mM
- Excitation / Emission : 491 nm / 509 nm
Description
- DiO is a lipophilic carbocyanine dye used to label cell membranes. It emits strong fluorescence when its long hydrocarbon chains are incorporated into a lipid bilayer. This product is a ready-to-use solution of DiO which can be used as a tracer in cell fusion, cell adhesion and chemotaxis.
Storage
- Store at room temperature (below 15 °C is recommended) and protect from light.
Directions for Use: Staining live cells
- Dilute DiO solution to 5 μM with culture medium.
- Remove medium from cells and replace with 5 μM DiO-containing medium.
- Incubate cells at 37 °C for 10 minutes.
- Remove medium and wash cells 3 times with PBS.
- Observe stained cell membranes via a fluorescence microscope.
Directions for Use: Staining fixed cells
- Remove culture medium and wash cells twice with PBS.
- Add 4% paraformaldehyde to cells and incubate at room temperature for 10 minutes.
- Dilute DiO solution to 5 μM with PBS.
- Remove 4% paraformaldehyde and add 5 μM DiO-containing PBS to cells.
- Incubate cells at 37 °C for 10 minutes.
- Remove medium and wash cells 3 times with PBS.
- Observe stained cell membranes via a fluorescence microscope.
Related Products
- D6202 DiI Solution [for Cell Membrane Staining]
- D6263 DiD Solution [for Cell Membrane Staining]
- D6540 DiR Solution [for Cell Membrane Staining]
- P3316 PKH 26 Solution [for Cell Membrane Staining]
Product Number | D6539 |
Physical State (20 deg.C) | Liquid |
Storage Temperature ![]() |
Room Temperature (Recommended in a cool and dark place, <15°C) |
Store Under Inert Gas | Store under inert gas |
Condition to Avoid | Air Sensitive |
Appearance | Colorless to Yellow clear liquid |
Functionality test | to pass test |
Pictogram |
![]() ![]() ![]() |
Signal Word | Danger |
Hazard Statements | H319 : Causes serious eye irritation. H360 : May damage fertility or the unborn child. H372 : Causes damage to organs through prolonged or repeated exposure. H373 : May cause damage to organs through prolonged or repeated exposure. H350 : May cause cancer. H402 : Harmful to aquatic life. H225 : Highly flammable liquid and vapor. |
Precautionary Statements | P501 : Dispose of contents/ container to an approved waste disposal plant. P273 : Avoid release to the environment. P270 : Do not eat, drink or smoke when using this product. P202 : Do not handle until all safety precautions have been read and understood. P240 : Ground/bond container and receiving equipment. P260 : Do not breathe mist or vapours. P210 : Keep away from heat/sparks/open flames/hot surfaces. No smoking. P233 : Keep container tightly closed. P201 : Obtain special instructions before use. P243 : Take precautionary measures against static discharge. P241 : Use explosion-proof electrical/ ventilating/ lighting/ equipment. P242 : Use only non-sparking tools. P264 : Wash skin thoroughly after handling. P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection. P370 + P378 : In case of fire: Use dry sand, dry chemical or alcohol-resistant foam to extinguish. P308 + P313 : IF exposed or concerned: Get medical advice/ attention. P337 + P313 : If eye irritation persists: Get medical advice/ attention. P305 + P351 + P338 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. P403 + P235 : Store in a well-ventilated place. Keep cool. P405 : Store locked up. |
UN Number (DOT-AIR) | UN1170 |
Class (DOT-AIR) | 3 |
Packing Group (TCI-A) | II |
HS Number | 3822.19.0080 |
Safety Data Sheet (SDS)
The requested SDS is not available.
Please Contact Us for more information.
Specifications
C of A & Other Certificates
Sample C of A
A sample C of A for this product is not available at this time.
Analytical Charts
The requested analytical chart is not available. Sorry for the inconvenience.