CAS RN: 530-62-1 | Product Number: C0119

1,1'-Carbonyldiimidazole [Coupling Agent for Peptides Synthesis]


Purity: >97.0%(T)
Synonyms:
  • 1,1'-Carbonylbis-1H-imidazole
  • CDI
Product Documents:
5G
₹2,000.00
Contact Us ≥80 
25G
₹3,280.00
Contact Us ≥100 
250G
₹15,200.00
32   ≥100 

*Upon orders receipt, Hyderabad stocks will be dispatched on the same day.
*Items available in Japan warehouse will be dispatched in 10-12 working days.
*INR price is exclusive of domestic taxes applicable.
*TCI frequently reviews storage conditions to optimize them. Please note that the latest information on the storage temperature for the products is described on our website.


Product Number C0119
Purity / Analysis Method >97.0%(T)
Molecular Formula / Molecular Weight C__7H__6N__4O = 162.15 
Physical State (20 deg.C) Solid
Storage Temperature Refrigerated (0-10°C)
Store Under Inert Gas Store under inert gas
Condition to Avoid Moisture Sensitive,Heat Sensitive
CAS RN 530-62-1
Reaxys Registry Number 6826
PubChem Substance ID 87565300
SDBS (AIST Spectral DB) 21181
Merck Index (14) 1819
MDL Number

MFCD00005286

Specifications
Appearance White to Light yellow powder to crystal
Purity(Neutralization titration) min. 97.0 %
Melting point 115.0 to 122.0 °C
Properties (reference)
Melting Point 118 °C
GHS
Pictogram Pictogram Pictogram
Signal Word Danger
Hazard Statements H302 : Harmful if swallowed.
H314 : Causes severe skin burns and eye damage.
Precautionary Statements P501 : Dispose of contents/ container to an approved waste disposal plant.
P260 : Do not breathe dusts or mists.
P270 : Do not eat, drink or smoke when using this product.
P264 : Wash skin thoroughly after handling.
P280 : Wear protective gloves/ protective clothing/ eye protection/ face protection.
P303 + P361 + P353 : IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P301 + P330 + P331 : IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P363 : Wash contaminated clothing before reuse.
P301 + P312 + P330 : IF SWALLOWED: Call a POISON CENTER/doctor if you feel unwell. Rinse mouth.
P304 + P340 + P310 : IF INHALED: Remove person to fresh air and keep comfortable for breathing. Immediately call a POISON CENTER/doctor.
P305 + P351 + P338 + P310 : IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Immediately call a POISON CENTER/doctor.
P405 : Store locked up.
Related Laws:
Transport Information:
UN Number UN1759
Class 8
Packing Group III
Application
TCI Practical Example: Condensation using 1,1'-Carbonyldiimidazole

Used Chemicals

Procedure

To a solution of N-carbobenzoxyglycine (2.10 g, 10 mmol) in anhydrous tetrahydrofuran (10 mL) was added 1,1'-carbonyldiimidazole (1.64 g, 10 mmol). The mixture was stirred at room temperature for 4 hours. L-tyrosine ethyl ester (2.10 g, 10 mmol) was added to the reaction mixture. The mixture was stirred at room temperature overnight. The solvent was removed under reduced pressure. The residue was dissolved in ethyl acetate (30 mL), treated with 1 mol/L HCl solution (50 mL), and stirred for 10 min. The organic layer was separated and the aqueous layer was extracted with ethyl acetate (20 mL x 2). The combined organic layers were washed with saturated aqueous NaHCO3 solution (30 mL), washed with brine (30 mL), dried over Na2SO4 and filtered. The solvent was removed under reduced pressure. The residue was purified by flash column chromatography (eluent: dichloromethane/ethyl acetate, 90/10→75/25→50/50) to obtain 1 as a white solid (3.54 g, 88%).

Experimenter's Comments

The reaction mixture was monitored by TLC (hexane/ethyl acetate = 5/1, Rf = 0.17) and 1H NMR. After the reaction mixture was concentrated and quenched by 1 mol/L HCl solution, the recrystallization with ethanol was conducted. Sticky white solid was precipitated at low temperature but it can't be filtered.

Analytical Data(Compound 1

1H NMR (400 MHz, CDCl3); δ 7.35 (m, 5H), 6.92 (d, J =8.24 Hz, 2H), 6.67(dd, 3J =8.24 Hz, 4J =1.83 Hz, 2H), 6.45(d, J =6.87 Hz, 1H), 5.69 (s, 1H), 5.40 (br s, 1H), 5.12 (s, 2H), 4.81(q, J =5.95 Hz, 1H), 4.18 (q, J =7.32 Hz, 2H), 3.84 (m, 2H), 3.03 (m, 2H), 1.27 (t, J=7.32 Hz, 4H)

13C NMR (101 MHz, CDCl3); δ 171.55, 168.74, 156.61, 155.24, 135.99, 130.50, 130.39, 128.57, 128.29, 128.14, 126.93, 115.52, 115.37, 67.30, 61.78, 61.50, 53.16, 44.31, 36.95, 14.17, 14.07.

Lead Reference


Application
Condensation of Amino Acides Using 1,1’- Carbonyldiimidazole

Typical Procedure:
To a solution of N-Cbz-glycine (2.09 g, 0.010 mol) in dry THF (10 mL) is added 1,1’-carbonyldiimidazole (CDI) (1.62 g, 0.010 mol). After stirring for 1.5 hour, L-tyrosine ethyl ester (2.09 g, 0.010 mol) is added to the solution and the reaction mixture is stirred overnight. Then THF is removed by an evaporator and 1 N-HCl (50 mL) is added. Cooling of the solution gives a solid. This is washed with water and 5% NaHCO3. The solid is filtered and washed with water again. After drying, the product is recrystallized from 50% ethanol to give ethyl N-Cbz-glycine- L -tyrosine ethyl ester (3.79 g, yield 95%).

References


PubMed Literature


Product Documents (Note: Some products will not have analytical charts available.)
Safety Data Sheet (SDS)
Please select Language.

The requested SDS is not available.

Please Contact Us for more information.

Specifications
C of A & Other Certificates
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The product with the lot number searched for has been discontinued and no related documentation is available.

Sample C of A
This is a sample C of A and may not represent a recently manufactured lot of the product.

A sample C of A for this product is not available at this time.

Analytical Charts
Please enter Lot Number Incorrect Lot Number. Please input only the 4-5 alphanumeric characters before the hyphen.

The requested analytical chart is not available. Sorry for the inconvenience.

The product with the lot number searched for has been discontinued and no related documentation is available.

Other Documents

Session Status
Your session will timeout in 10 minutes. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page. minute. You will be redirected to the HOME page after session timeout. Please click the button to continue session from the same page.

Your session has timed out. You will be redirected to the HOME page.

TCI
Please enter the required fields (*)
Please enter valid mobile number
New User? *
Add me to your mailing list *

Thank you for signing up!


New subscribers will get FREE TCI Gifts!
We will notify you of further updates on our New products, Offers, Schemes, Discounts, etc.


OK