Published TCIMAIL newest issue No.201
Maximum quantity allowed is 999
CAS RN: 2249891-88-9 | Numéro de produit: A3349
2-(Allylsulfonyl)-5-methylpyridine
Pureté: >95.0%(GC)
- 5-Methyl-2-(2-propen-1-ylsulfonyl)pyridine
| Taille | Prix unitaire | Belgique | Japon * | Quantité |
Informations d'expédition
|
|---|---|---|---|---|---|
| 200MG |
83,00 €
|
Contactez-nous | ≥40 |
|
|
| 1G |
291,00 €
|
Contactez-nous | 38 |
|
*Stock disponible en Belgique : Expédition le jour même
*Stock disponible au Japon : Veuillez consulter la simulation d'expédition pour une estimation des délais d'expédition (hors articles réglementés et expédition avec Carboglace)
| Numéro de produit | A3349 |
Pureté / Méthode d'analyse
|
>95.0%(GC) |
| Formule moléculaire / poids moléculaire | C__9H__1__1NO__2S = 197.25 |
| Etat physique (20 ° C) | Solid |
Condition de stockage
|
Refrigerated (0-10°C) |
| Condition à éviter | Heat Sensitive |
| CAS RN | 2249891-88-9 |
| Numéro de registre de Reaxys | 33705834 |
| Identifiant de la substance PubChem | 468590249 |
| Appearance | White to Light yellow powder to crystal |
| Purity(GC) | min. 95.0 % |
| NMR | confirm to structure |
| Pictogramme |
|
| Mot de signal | Attention |
| Mentions de danger | H315 : Provoque une irritation cutanée. H319 : Provoque une sévère irritation des yeux. |
| Conseils de prudence | P264 : Se laver la peau soigneusement après manipulation. P280 : Porter des gants de protection/ un équipement de protection des yeux/ du visage. P302 + P352 : EN CAS DE CONTACT AVEC LA PEAU: Laver abondamment à l’eau. P337 + P313 : Si l'irritation oculaire persiste: consulter un médecin. P362 + P364 : Enlever les vêtements contaminés et les laver avant réutilisation. P332 + P313 : En cas d'irritation cutanée: consulter un médecin. |
| N ° SH (import / export) (TCI-E) | 2933399999 |
-
Used Chemicals
-
Procedure
-
To a pressure resistant test tube was charged with 2-(allylsulfonyl)-5-methylpyridine (592 mg, 3.0 mmol, 1.5 equiv.), palladium(II) acetate (22 mg, 0.1 mmol, 5 mol%), PtBu2Me·HBF4 (50 mg, 0.2 mmol, 10 mol%), cesium carbonate (1.30 g, 4.0 mmol, 2.0 equiv.). The test tube was purged with nitrogen and DMF (10 mL) and 4-bromoanisole (0.25 mL, 2.0 mmol, 1.0 equiv.) were added in one portion at room temperature. The resulting mixture was stirred at 150 °C for 17 h. The reaction mixture was cooled to room temperature and quenched with water (10 mL). The organic layer was extracted with diethyl ether (100 mL x 3), dried with Na2SO4 (20 g) and then concentrated under reduced pressure. The crude product was purified by column chromatography on silica gel (ethyl acetate : hexane = 5 : 95 ~ 18 : 82) to afford the corresponding compound 1 as yellow solid (196 mg, 49%).
-
Experimenter’s Comments
-
The reaction mixture was monitored by TLC (ethyl acetate : hexane = 1 : 5, Rf = 0.37).
DMF was dehydrated by MS4A for 16 h and degassed by bubbling with nitrogen gas for 30 min.
-
Analytical Data(2-(4-Methoxyphenyl)-5-methylpyridine (1))
-
1H NMR (400 MHz, CDCl3); δ 8.47 (s, 1H), 7.92 (dd, 2H, J = 9.2, 1.8 Hz), 7.50-7.59 (m, 2H), 6.99 (dd, 2H, J = 9.2, 1.8 Hz), 3.86 (s, 3H), 2.35 (s, 3H).
13C NMR (101 MHz, CDCl3); δ 160.1, 154.3, 149.7, 137.4, 131.8, 130.9, 127.9, 119.4, 114.0, 55.3, 18.1.
-
Lead Reference
-
- Heterocyclic Allylsulfones as Latent Heteroaryl Nucleophiles in Palladium-Catalyzed Cross-Coupling Reactions
Documents
[TCI Practical Example] Cross-Coupling Reaction Using the Allylsulfonylpyridine Derivative
Fiche de sécurité (FDS)
La FDS demandée n'est pas disponible.
Nous contacter pour plus d'informations.
text.sds.search.errormsg.content.1.kishida
Spécifications
Les spécifications demandées ne sont pas disponibles.
Nous contacter pour plus d'informations.
text.specification.search.errormsg.content.1.kishida
CoA et autres Certificats
Veuillez vérifier que le numéro de lot que vous avez saisi est correct. Il s'agit de 4 à 5 caractères alphanumériques avant le trait d'union. Veuillez vérifier soigneusement si O (alphabet) ou 0 (chiffre), "I (alphabet) ou 1 (chiffre) en particulier.
Si les informations sont correctes et que vous ne pouvez toujours pas voir le certificat demandé, veuillez nous contacter.
text.certificate.analysis.pdf.errormsg.content6.kishida
Exemple de CoA
Un échantillon CoA pour ce produit n'est pas disponible pour le moment.
Graphiques analytiques
Le tableau analytique demandé n'est pas disponible. Nous sommes désolés pour ce désagrément.